How to login to Safe Fleet/Seon DVR locally
How to login to Safe Fleet/Seon DVR locally
PURPOSE
The purpose of this document is to establish a clear framework for the local login to the onboard Seon system. This framework aims to enforce best practices, ensure standard compliance, and mitigate potential failures.
SCOPE
This document's scope encompasses a single procedure on how to connect locally.
RESPONSIBILITIES
IT is responsible for any procedures in which a connection is made to any MVTA hardware.
NOTE – Factory default login to front port is set to.
Username – Admin
Password – 11111111
TH 8 System
- Change the NIC address on your computer to the following.
-
IP address - 192.168.0.101
-
Subnet Mask - 255.255.255.0
-
LAN Gateway - 192.168.0.100
- Plug an ethernet cable into your pc and the front port of the DVR.
- Use Edge in IE mode and navigate to 192.168.0.100
- Login with the following credentials
-
Username – Admin
-
Password – minnemn0
All other Safe Fleet/Seon systems
- Change the NIC address on your computer to the following.
-
IP address – 10.10.9.2
-
Subnet Mask - 255.255.255.0
-
LAN Gateway – 10.10.9.1
- Plug an ethernet cable into your pc and the front port of the DVR.
- Use Edge in IE mode and navigate to 10.10.9.2
- Login with the following credentials
-
Username – Admin
-
Password – minnemn0